Large-mode-area double-clad tapered fiber for extreme-peak-power, cladding-pumped amplifiers — up to 0.5 MW nonlinear threshold with diffraction-limited output.
Large mode area ytterbium doped double clad polarization-maintaining tapered fiber YDF-DC-40/400-PM-TPR-2.5-A series is designed for operation without any power degradation in extremely high-peak-power cladding-pumped amplifiers. The new tapered fiber design has a single-mode end (typical dimension is 8/80 µm) for signal input and a very-large-mode-area end (typical dimension is 40/400 µm) for signal output and pump input. The all-glass double-clad fiber design (based on highly F-doped second cladding with typical NA=0.26) allow simple polishing of the thick 400 µm fiber end. Due to a high Yb concentration and a short tapered fiber length amplifiers based on this fiber has the highest threshold of nonlinear effects over the market (up to 0.5 MW) together with the diffraction limited beam quality at the output.
FIBER SPECIFICATIONS;Signal input end;Signal output / Pump input end
Core diameter, μm; 9 ± 1; > 40
Clad diameter, μm; 90 ± 10; 400 ± 50
Cutoff wavelength, μm; < 1.0; -
MFD; 10.0 ± 2.0; > 24 (25 ÷ 30 typical)
Core NA; 0.09 ± 0.01;0.09 ± 0.01
Clad NA; > 0.22;> 0.22
Clad shape; PANDA with F-doped second cladding;PANDA with F-doped second cladding
Clad absorption (915 nm), dB/m; > 5;> 5
Clad absorption (976 nm), dB/m; > 20;> 20
Core background loss (1150 nm),dB/km; < 50;< 50
Length, m; 2.5 ± 0.5;2.5 ± 0.5
Photodarkening resistance; > 20 times better compare to the Al2O3-SiO2 Yb-doped fiber;> 20 times better compare to the Al2O3-SiO2 Yb-doped fiber
Customization — Short tapered fiber with length ~ 1.7 m for operation near 1030 nm are available on the request; other parameters are available on the request.
Highest nonlinear threshold on the market — up to 0.5 MW peak power before onset of nonlinear effects, thanks to high Yb concentration and a short taper length.
Diffraction-limited beam quality — clean output beam even at extreme peak powers.
All-glass double-clad design — highly F-doped second cladding (NA ≈ 0.26) allows simple, reliable polishing of the thick 400 µm end.
Dual-end architecture — single-mode 8/80 µm input, LMA 40/400 µm output, no extra mode-matching components needed.
Polarization-maintaining — preserves linear polarization through the taper for coherent/narrow-linewidth systems.
No power degradation — engineered for stable operation without power roll-off over time.
Why it matters: in cladding-pumped amplifiers, peak power is usually capped by nonlinear effects (SBS, SRS) long before the fiber's damage threshold. The short, high-concentration taper design of YDF-DC-40/400-PM-TPR-2.5-A pushes that nonlinear ceiling far higher than standard step-index LMA fibers — while keeping the output beam diffraction-limited.
If you are interested in purchasing our products you can write to us!